SyntaxFlow

Glass · Standards

EN 16612 explained: glass thickness under wind load

EN 16612 (EN 16612:2019, «Glass in building — Determination of the lateral load resistance of glass panes by calculation») is the European standard for working out whether a glass pane carries a load across its face, such as wind. The glass thickness calculator takes its design strength formula and checks two things on a pane supported on four edges: the bending stress, against that strength, and the deflection, against a limit you choose. This page summarises what the calculator implements; it does not reproduce the standard, which is sold by the national standards bodies. The title of the standard is taken from the catalogue entries below, consulted on 8 November 2026.

Open the glass thickness calculator with the example →

What the calculator works out with it

What it asks for

The design strength, in the form of EN 16612

annealed: f_g;d = k_mod · k_sp · f_g;k / γ_M;A prestressed: f_g;d = k_mod · k_sp · f_g;k / γ_M;A + k_v · (f_b;k − f_g;k) / γ_M;v
Glass10-minute wind, N/mm²5-second gust, N/mm²
Annealed float — EN 57218.525.0
Heat-strengthened — EN 186339.445.8
Fully tempered (toughened) — EN 1215081.087.5

Design strengths as the calculator computes them, from its own code.

What the site assumes

A rectangular pane simply supported on four edges, linear (small-deflection) plate theory with the classical coefficients α and β interpolated by aspect ratio: σ = β·q·b²/t² and w = α·q·b⁴/D, with E = 70 000 N/mm² and ν = 0.23. Design strength in the form of EN 16612 with kmod = 0.663·t−1/16 (a 10-minute wind, 0.74, by default; a 5-second gust, 1.00, on request), γM;A = 1.8 and γM;v = 1.2. Laminated glass by its effective thickness, with no shear transfer and with full transfer. The input is the factored design pressure. The wind lab is a view of this same engine.

Where the calculator departs from the textbook or where we could not check the standard, it says so:

An example worked by the calculator

A pane of 1200 × 2200 mm, 10 mm fully tempered, under 1.20 kN/m², a 10-minute wind and a deflection limit of short span / 65:

Open this example in the calculator. The calculator page works the same pane out by hand, line by line.

What it leaves out

The calculator is run against 12 published reference cases, side by side with the published figure and the tolerance we accept, on how we check the calculations.

A pre-dimensioning aid for professionals: not a structural calculation, not signed by an engineer, and no substitute for the standard and the national annex that apply to the project.

Sources

Questions people ask

What does EN 16612 cover?
EN 16612:2019, «Glass in building — Determination of the lateral load resistance of glass panes by calculation», is the European standard for working out the resistance of glass panes to loads across their face, such as wind. The site's glass thickness calculator uses its design strength formula and checks bending stress and deflection of a pane supported on four edges.
Does EN 16612 set a deflection limit?
No. As the calculator page says, the deflection limit is a project or national requirement; the calculator offers short span / 60, 65, 100 and 175 and shows which check governs.
What design strength does the calculator give toughened glass?
81.0 N/mm² for a 10-minute wind and 87.5 N/mm² for a 5-second gust, in the form of EN 16612; annealed float glass gets 18.5 and 25.0 N/mm².